Fig. 2. Placement of type-K 1/16-inch-thick Inconel thermocouples


 

Decades of research show that the cooling rates for helium are far better than those for argon. However, a current government policy dilemma is likely to have far-reaching repercussions for the future.



Problem

Scientists have recently warned that helium – one of the world’s most commonly used inert gases – is being depleted at astonishing rates. What has caused this shortage of the second lightest element in the universe? One has to look no further than our own government.

In 1996, the U.S. passed a law[1] stipulating that the U.S. National Helium Reserve, the largest store of helium in the world, located outside of Amarillo, Texas, must sell off all its inventory by 2015, irrespective of the market price. The law also dictates that an equal amount must be sold each year, regardless of global demand.

Since the planet has taken 4.7 billion years to accumulate our helium reserves, and there is no artificial way to manufacture the gas, many scientists predict the world will run out of helium within 25-30 years. It is inevitable, therefore, that heat treaters purchasing helium will see costs rise exponentially unless the U.S. government reconsiders its policy of selling off its national helium reserves.



Enlarged Image

  

Fig. 1. Typical 56,125-pound titanium test load

Solution

Historically, when vacuum processing large 55,000-pound loads of titanium coils, Solar Atmospheres of Western Pa. would typically utilize 100% helium as the backfill gas of choice. As the prices for helium escalated, a proposed solution was to sacrifice the more efficient cooling rates by using a less-expensive inert gas – argon. It was quickly realized that using such a dense gas for cooling heavy loads was a huge mistake.

In 1992, Air Products and Chemicals U.S. Patent #5,173,124 discovered that cooling rates resulting from blending helium and argon together in specified ratios would be greater than those from helium alone under similar conditions of turbulent flow. The patent was also based on the cooling results of a rather small load of 1,844 pounds. Solar Atmospheres decided to perform similar experiments on very large loads in excess of 50,000 pounds.



Enlarged Image

  

Test

A total of six 2-bar quenching tests were performed in a 5-foot x 5-foot x 24-foot Solar Manufacturing-patented car-bottom vacuum furnace (Fig. 1). Each furnace load consisted of a cast workload grid and special customer-supplied fixturing base plates weighing a total of 6,125 pounds. The normal weight of each titanium coil was 10,000 pounds. Therefore, each five-coil load equaled a total weight of 56,125 pounds. Temperature measurements were taken from three work thermocouples firmly embedded in the innermost core of the center coil (Fig. 2).

The first two cooling tests performed utilized a backfill of each of the pure inert gases alone. Cooling speed with 100% helium versus 100% argon on identical loads was faster by a factor of four (five hours vs. 20). Cooling these massive workloads was enhanced by over-speeding the two 300-hp blower motors with variable-frequency drives (VFD). These VFDs allow the motors to perform at a maximum motor current that adapts to the type of process gas selected. The use of argon at 2-bar allows the motors to operate at approximately 3,000 rpm, whereas the less-dense helium allows the motors to operate at 5,000 rpm at only one-third of the motor current needed for argon.

Another promising method of enhancing cooling time was to control the backfill make-up gas. In all of the tests, once the chamber was backfilled to 2-bar pressure and cooling was initiated, no additional make-up gases were added, thereby conserving cooling gas. As the temperature in the furnace decreased, the chamber pressure also decreased. This pressure drop allowed the VFDs to speed up the motors, providing faster velocities through the gas nozzles.

The next four cooling tests consisted of various ratios of the two gases in the blend. The initial blend test was 20% argon-80% helium, which was similar to the optimum blend cited in the Air Products patent. The total cooling time averaged 10 hours. The next test used a 50%-50% blend of argon and helium. The total cooling time again was 10 hours. The next test used 80% argon-20% helium. The cooling rate remained at 10 hours. The last test, in an effort to save as many helium molecules as possible, tested a 90% argon-10% helium mix. The cooling rate surprisingly remained the same as all of the previous blends. Figure 3 summarizes the results and costs associated with each backfill.



Enlarged Image

  

Fig. 4. Cooling-rate curves showing effects of different backfill gases

Conclusion

Although the thermal conductivity of helium is 10 times that of argon, there is a cumulative dynamic effect on the quantity of heat transmitted when blending gases, independent of the ratios. For the immediate future, Solar Atmospheres is employing this characteristic to backfill automatically at a 90% argon-10% helium mixture,[3] with no additional make-up gas during the 10 hours of cooling.

The future for the use of helium is certainly very bleak. In fact, at the time of this writing, our gas supplier[4] imposed a helium force-majeure measure upon us. These helium allocations will definitely last until the end of 2012 – if not beyond. Even if helium gas supplies do not vanish completely, the cost will become extremely prohibitive. Not only will heat treaters be severely affected, but other industries such as medical (MRI scanners), aerospace (rockets and air ships) and welding operations will also be impacted. IH

For more information: Contact Robert Hill, Solar Atmospheres of Western Pennsylvania, 30 Industrial Road, Hermitage, Pa. 16148; tel: 724-982-0660; e-mail: rah@solarwpa.com; web: www.solaratm.com

Notes:
1. Public Law 104-273, Helium Privatization Act of 1996.
2. Based on kWh to drive cooling motors.
3. Solar Atmospheres Inc. Proprietary Technology
4. Air Products and Chemicals, Inc. of Allentown, Pa.