This website requires certain cookies to work and uses other cookies to help you have the best experience. By visiting this website, certain cookies have already been set, which you may delete and block. By closing this message or continuing to use our site, you agree to the use of cookies. Visit our updated privacy and cookie policy to learn more.
This Website Uses Cookies By closing this message or continuing to use our site, you agree to our cookie policy. Learn MoreThis website requires certain cookies to work and uses other cookies to help you have the best experience. By visiting this website, certain cookies have already been set, which you may delete and block. By closing this message or continuing to use our site, you agree to the use of cookies. Visit our updated privacy and cookie policy to learn more.
Direct Spark Ignition Control
February 19, 2006
Fenwal Controls
The Series 35-62 microprocessor-based dual point direct spark gas ignition system is designed for commercial and industrial OEM customers. Developed for gas-fired applications utilizing two separate burners, the 35-62 controls a single gas valve and simultaneously lights and monitors both gas burners. The system includes 24 VAC microprocessor-based DSI control, system diagnostics LED, multiple tries for ignition (OEMs specify either one of three attempts as well as timings), custom pre-purge and inter-purge timings (0, 15 or 30 seconds standard), remote flame sensing with dual-flame sensor inputs, full-time flame sensing, dual-flame sense test pins for ease of troubleshooting.www.fenwalcontrols.comInfo # 269