| Fig. 2. Vertical Test Specimen (VTS) made from Inconel 600 and brazed with BNi-2 nickel-based brazing filler metal (BFM). The gap clearance is 0.000" (i.e. the metals touch) at the base and gradually opens up to a 0.012" (0.30mm) clearance at the top. Note the capillary break at a gap clearance of 0.006" (0.15 mm). During the furnace brazing cycle, the liquid BNi-2 filler metal flowed and was pulled upwards by capillary action until the gap was 0.006" (0.15mm), at which point it could rise no further.
|
|
The VTS, which was developed by the late Robert L. Peaslee, provides a unique way to determine exactly what kind of braze clearances can be tolerated in your particular furnace with your particular base metals and BFMs. The shape of the VTS is such that when the filler metal is placed on the VTS at the base of the vertical "V" (where the gap clearance is "zero"), the BFM will melt during the brazing cycle and be drawn by capillary action vertically up the gap between the two angled legs of the specimen. The BFM flow will stop (capillarity is broken) when the gap between the legs becomes too great for the BFM to rise any further, according to the particular conditions of that furnace cycle (time, temp, ramp rates, etc.), atmosphere quality and BFM interaction with the base metal in that particular furnace run. Yes, they can vary in the furnace from cycle to cycle.
In Fig. 2, you can see the results of an actual VTS in which the base metal was Inconel 600 and the BFM was BNi-2. The VTS was brazed in a vacuum furnace at 10
-4 Torr and held at a temperature of 1900°F (1040°C) for 15 minutes.
Note that the BNi-2 BFM was drawn by capillary action up into the vertical joint and was able to rise to a height where the gap was 0.006" (0.15 mm) but no higher. Above that point, the gap was too large for the conditions noted in that furnace cycle.
Some people would respond to this by saying, "Great! I can braze parts together with a gap of 0.006" (0.15mm). Wow!"
No, that's WRONG! At 0.006" (0.15mm) in this actual test, capillarity could not continue beyond that gap clearance! So, if in your own samples the gaps are nominally about 0.006" (0.15mm), you will probably have some portions of the joint that are a little less than 0.006" (0.15mm) and other areas in the joint that are greater than 0.006" (0.15mm). Consequently, some of those braze gaps will not be able to fill because they are too large.